2b. Jail generator stack design
Laserfiche
>
Public
>
County Commission
>
2008
>
10-20-2008
>
Regular agenda
>
2b. Jail generator stack design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/17/2008 10:54:27 AM
Creation date
10/14/2008 11:04:54 AM
Metadata
Fields
Template:
Commission
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />John'son, Bonnie <br /> <br />From: <br />Sent: <br />To: <br />Cc: <br /> <br />Johnson, Bonnie <br />Monday, September 29,2008 12:08 PM <br />'Rick Hoganson' <br />Montplaisir, Michael; Burdick, Birch; Laney, Paul; Perez, Carlos; {Cass}-Commissioners; <br />{Cass}-Bldg & Grounds <br />JAIL GENERATOR STACK <br /> <br />Subject: <br /> <br />Importance: <br />Attachments: <br /> <br />Low <br /> <br />Jail generator cooling tower 002.jpg <br /> <br />~ <br /> <br />Jail generator <br />cooling tower 0... <br /> <br />Rick- About two months ago, the jail administration moved inmates from the new G Pod to the new H Pod, so we could <br />"use" the H Pod before the warranty expired. TOday, while Tom from, Foss, was on the roof with us to look at our <br />structural problems with the generator cooling tower, we started up the generator. This would be the second start up <br />since we began using the H pod. We had the same poor result. Diesel fumes from the generator stack were sucked into <br />the fresh air intakes in the H Pod. I have attached the photo from last week to show the location of the generator stack <br />and the fresh air intake. <br /> <br />Two times we have used the generator since the inmates were moved, and both times the pod has filled with fumes. I <br />suspect, the high wall addition of the new Pod wall has worked to create a "swirl" of the diesel fumes in this location <br />rather than allowing the fumes to dissipate. Can you check with the design team regarding this? I know the set-up meets <br />code for the separation distance, but we are not getting the exhaust our of the comer. Let me know what you learn. <br />Thanks. <br /> <br />Bonnie Johnson <br />County Administrator <br />iohnsonb@casscountvnd.Qov <br />701-241-5720 (voice) <br />701-297-6020 (fax) <br /> <br />1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.