i. Septic system permit fees--Fargo Cass Public Health
Laserfiche
>
Public
>
County Commission
>
2008
>
04-07-2008
>
Consent agenda
>
i. Septic system permit fees--Fargo Cass Public Health
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2008 12:42:09 PM
Creation date
4/1/2008 12:41:04 PM
Metadata
Fields
Template:
Commission
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />2. No tank or compartment thereof shall have an <br />inside horizontal dimension less than 24 inches. <br /> <br />3. Inlet and outlet connections of the tank shall be <br />submerged by means of baffles or sanitary tees. <br /> <br />4. The space in the tank between the liquid surface <br />and the top of the inlet and outlet baffles shall be <br />less than 20 percent of the total required liquid <br />capacity, except that in horizontal cylindrical tanks, <br />this space shall not be less than 15 percent of the <br />total required liquid capacity. <br /> <br />5. Inlet and outlet baffles shall be constructed of acid <br />resistant concrete, acid resistant fiberglass or <br />plastic. <br /> <br />6. Sanitary tees shall be affixed to the inlet or outlet <br />pipes with a permanent water-proof adhesive. <br />Baffles shall be integrally cast with the tank, <br />affixed with a permanent water-proof adhesive or <br />affixed with stainless steel connectors, top and <br />bottom. <br /> <br />7. The inlet baffle, or sanitary tee, shall extend at <br />least six inches, but not more than 20 percent of <br />the total liquid surface and at least one inch above <br />the crown of the inlet sewer. <br /> <br />8. The outlet baffle, or tee, and the baffles between <br />compartments shall extend below the liquid <br />surface, a distance equal to 40 percent of the <br />liquid depth, except that the penetration of <br />indicated baffles or sanitary tees for horizontal <br />cylindrical tanks shall be 35 percent of the total <br />liquid depth. They also shall extend above the <br />liquid surface. In no case shall they extend less <br />than six inches above the liquid surface. <br /> <br />19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.